Floating Left
PABX Panasonic

Pesanan Di Jamin Sampai Tujuan Info - Terbaru Harga dan Stok Hubungi 081280562777

Login
Search
Search:
Product Scroller
Information
Banner
POS INDONESIA
tiki
jne
Herona
mexbarlian

»

#22 of 34 | prev product Prev - Next next product
printer email

product arrow EATON EDX3000HXL

EATON EDX3000HXL
Price Rp 9.500.000

UPS EATON EDX3000HXL

CONSTRUCTION

  • Model : EDX3000HXL-LCD
  • Rating : 3000VA / 2400W
  • Technology : VFI, on-line double conversion

Dimensions: W x D*x H mm

  • Allow 150mm rear clearance for connections & air flow : 190 x 433 x 318
  • Weight : 14kg

ENVIRONMENTAL & SAFETY

  • Ambient service temperature : Power electronics part: 0 to 40C, Battery part: 5 to 25C without reducing battery life
  • Ambient storage temp. : 0°C to +45°C
  • Maximum service altitude : 1000m above sea level
  • Relative humidity : 20 to 90%, no condensation allowed
  • Degree of protection : IP21 (EN60529)
  • Acoustic Noise : <50 dB @1m, Normal mode, typical load, battery fully charged
  • Standards : EMS & EMI: Complies with IEC61000-4-2 Level 4, IEC61000-4-3 Level 3, IEC61000-4-4, Level 4, IEC61000-4-4 Level 4, IEC62040-1, EN55022 Class B
  • Safety: GB4943-2001

POWER CONNECTIONS

  • Input : C20 16 Amp
  • Output : (4) C13 10A & Hardwired, 2mm2 maximum cable size (stranded cable)

USER INTERFACE

  • Display : LED mimic diagram + LCD Display with measurements (Input/Output/Bypass V & Hz, Battery V & % capacity & remaining time and level indicator, Load % & level Indicator, Alarm codes)
  • Communication Ports : 1 off Intelligent-Slot (Empty), 1 x RS232 DB9 Serial Port
  • Optional : Intelligent Slot cards; AS400 Relay, Web/SNMP, Modbus

ELECTRICAL CHARACTERISTICS – INPUT

  • Rated input voltage : 220V
  • Input voltage tolerance (with linear load) :
    185±5V – 300±5V at >90% load,
    160±5V – 300±5V at 71 – ≤90% load,
    150±5V – 300±5V at 66 – ≤70% load,
    130±5V – 300±5V at 56 – <65% load,
    110±5V – 300±5V at ≤55% load
  • Bypass Voltage Tolerance : 80 – 286V±5% (Default 180-264V ±5%, user adjustable)
  • Operating Frequency : 50/60Hz auto sensing; Tolerance (46/56 ±0.5) Hz Low, (54/64±0.5) Hz High
  • Input current distortion : <10% THDi
  • Input power factor @ Pnom : 0.98pf
  • Input Current (at rated load with fully charged battery) : 13.6A
  • Input protection rating (MCB) : 16A

ELECTRICAL OUTPUT CHARACTERISTICS – NORMAL MODE

  • Rated apparent/active power : 3000VA / 2400W
  • Transfer–normal to stored energy : No break
  • Rated output voltage : 220V
  • Output voltage variation : ±2%
  • Crest factor : 3:1
  • Rated output frequency : 50Hz (default) or 60Hz
  • Output frequency regulation : On Line Mode: Follows bypass frequency
  • Total output voltage distortion : ≤4% Linear Load, ≤7% Non Linear Load
  • Frequency Slew Rate : 1Hz/sec
  • Load power factor range : 0.7 – 1.0
  • Number of output phases : 1 Phase
  • Overload (Normal Mode, Resistive Load) : 108% ±5% ≤47 seconds, 150-200% ±5% ≤25 seconds
  • Output voltage variation – dynamic load : ±6% max from 20%-100%-20% load step or vice versa
  • Recovery to nominal : voltage ±10% within 60ms

ELECTRICAL OUTPUT CHARACTERISTICS – STORED ENERGY

  • Rated apparent/active power : 3000VA / 2400W
  • Waveform : Sine Wave
  • Rated output voltage : 220V
  • Output voltage variation : ±2%
  • Crest factor : 3:1
  • Rated output frequency : 50Hz (default) or 60Hz
  • Output frequency regulation : ±0.05Hz
  • Total output voltage distortion : <3% Linear Load, <7% Non Linear Load
  • Load power factor range : 0.7 – 1.0
  • Number of output phases : 1 Phase
  • Output Overload (Battery Mode) : 108% ±5% ≤47 seconds, 150-200% ±5% ≤25 seconds

EFFICIENCY (Input/Output)

  • Efficiency : at 100% linear
  • load : >85%

BATTERY

  • Internal Battery Type : Valve Regulated Lead Acid, AGM, 3-5 year design life at 25oC
  • Charging voltage : 2.275V/Cell ± 1%

Charger Capacity

  • Initial Charging current : 8.0A ±1.5A
  • End V/Cell, >23% Load : 1.64V
  • End V/Cell, ≤23% Load : 1.8V
  • Internal Battery Re-charge time Internal Battery: <5 hours to recover 90% of nominal backup
  • External Battery: Dependant on battery capacity
  • Battery Nominal Voltage : 96V (48 Cells)

UPS Internal Battery

  • Configuration (H Models) : 8 x 12V 7.2Ah
  • Battery Circuit Protection Rating : 60A
  • Battery Run Times : Internal battery (H Models)
  • Full Load / Half Load : 5 / 15 mins

BYPASS CHARACTERISTICS

  • Type of bypass : In-Built Automatic Relay Bypass
  • Transfer Time : <4ms